Steel solid fuel boiler with automatic fuel supply ATON КСТ-МП is a universal product for the regions, where the question of gasification has not yet been resolved. The model range of solid fuel boilers is introduced by capacities from 100 до 6000 kW.
The main purpose is heating of residential, public and industrial premises using solid fuel. As fuel for solid fuel boilers is using sawdust, chips and pellets.
Boilers are manufactured from high quality steel with a thickness of 5-8 mm (depending on power of boiler). The boiler is equipped with an efficient heating system primary and secondary air. The supplied fan air passes through the double wall of the heat exchanger of the boiler and is heated to 120-200°C, after which is fed into the furnace.
| Parameter name | unit | КСT-МП 100 | КСT-МП 150 | КСT-МП 200 | КСT-МП 250 | КСT-МП 300 | КСT-МП 400 | КСT-МП 500 |
| Nominal thermal power | kW | 99 | 150 | 200 | 250 | 300 | 400 | 500 |
| Type of fuel | Pellets (fraction up to 30 mm) | |||||||
| Efficiency | % | 85…..89 | 85…..89 | 85…..89 | 85…..89 | 85…..89 | 85…..89 | 85…..89 |
| The maximum temperature of the coolant at the outlet of the boiler | °С | 95 (by spec. order 115) | ||||||
| The minimum temperature of the coolant at the enter to the boiler | °С | 60 | 60 | 60 | 60 | 60 | 60 | 60 |
| Working pressure, not more | Mpa | 0,3 (by spec. order 0,6) | ||||||
| Volume of water in the boiler | m3 | 0,5 | 0,55 | 0,6 | 0,68 | 1 | 1,2 | 1,2 |
| Volume of water circulating through the boiler at ∆ t =25 °C" | m3/h | 3,44 | 5,16 | 6,88 | 8,6 | 10,32 | 13,76 | 17,2 |
| Hydraulic resistance | Mpa | 0,02 | 0,02 | 0,02 | 0,02 | 0,02 | 0,02 | 0,02 |
| Temperature of exhaust gas, not less | °С | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| The exhaustion behind the boiler, not more | Pa | 400 | 400 | 400 | 400 | 400 | 400 | 400 |
| Emissions, not more | ||||||||
| СО | mg/m3 | 1250 | 1250 | 1250 | 1250 | 1250 | 1250 | 1250 |
| Nox | mg/m3 | 500 | 500 | 500 | 500 | 500 | 500 | 500 |
| Installed capacity of electrical equipment (base), not more | kW | 0,5 | 0,5 | 0,5 | 0,53 | 0,53 | 0,53 | 0,5334 |
| The response time automation protection, not more | sec | 3 | 3 | 3 | 3 | 3 | 3 | 3 |
| Estimated fuel consumption | ||||||||
| pellet (Qn 4200 kcal, W 6%)) | kg/h | 22,05 | 33,10 | 44,10 | 55,12 | 66,14 | 88,19 | 110,24 |
| Connection sizes | ||||||||
| - connection coolant T1 | mm | 65 | 65 | 65 | 65 | 80 | 80 | 80 |
| - pipe PCK | inch | 1 1/2'' | 1 1/2'' | 2хG 1 1/2" | 2хG 1 1/2" | 2хG 1 1/2" | 2хG 1 1/2" | 2хG 2" |
| - chimney AxB | mm | 244х244 | 250х250 | 290х290 | 290х290 | 290х290 | Ø309 | 380х980 |
| Overall dimensions of the boiler without a safety valve | ||||||||
| - height H | mm | 2250 | 2240 | 2490 | 2430 | 3000 | 2585 | 3100 |
| - width L | mm | 1800 | 1830 | 2370 | 2150 | 2400 | 2580 | 3150 |
| - depth W | mm | 1600 | 1770 | 1815 | 2335 | 2350 | 2545 | 2545 |
| Boiler weight (without water) | kg | 1070 | 1500 | 2280 | 2300 | 2600 | 3310 | 3650 |