Parapet wall mounted gas boilers ATON Compact - are devices with the closed combustion chamber.
The design allows the use of boilers in heating systems with natural circulation (in areas not equipped with chimneys). The combustion gases and the air intake for combustion by means of a special twin-tube horizontal air&smoke flue through the external wall of the building.
The range of parapet wall gas boilers ATON Compact represented in capacities from 7 to 16 kW.
Boilers do not depend on electricity, installed near the outer wall.
They are made in single-and double-circuit versions. In the double-circuit boilers to heat water for household needs using a tubular flow-through serpentine heater made of copper (a metal with high thermal conductivity).
A typical feature of the boiler is universality of their connection, which provides additional comfort during the project and construction works.
Parameter title | units | 7Е (mini) |
7EB | 10Е | 10ЕВ | 12,5Е | 12,5ЕВ | 16Е | 16ЕВ |
Fuel | Natural gas | ||||||||
Efficiency, not less | % | 90 | 90 | 90 | 90 | 90 | 90 | 90 | 90 |
Nominal heat capacity | kW | 7 ±0,35 |
7 ±0,35 |
10 ±0,5 |
10 ±0,5 |
12,5 ±0,625 |
12,5 ±0,625 |
16 ±0,8 |
16 ±0,8 |
Maximal gas consumption, not more | m³/h | 0,78 | 0,78 | 1,12 | 1,12 | 1,39 | 1,39 | 1,78 | 1,78 |
The water consumption for hot water supply by heating to 35±5ºС | l/min | - | 2,7 | - | 3,8 | - | 5,0 | - | 6,7 |
Сhimney length: | |||||||||
inner diameter | mm | 130 | 130 | 130 | 130 | 130 | 130 | 130 | 130 |
outside diameter | mm | 238 | 238 | 238 | 238 | 238 | 238 | 260 | 260 |
length | mm | 385 - 530 | |||||||
Overall dimensions: | |||||||||
Height | m | 650 | 700 | 700 | 700 | 700 | 700 | 700 | 700 |
Width | mm | 420 | 520 | 520 | 520 | 630 | 630 | 740 | 740 |
Depth | mm | 245 | 270 | 270 | 270 | 245 | 245 | 270 | 275 |
Weight, not more | kg | 32,5 | 41,5 | 40 | 41,5 | 48 | 50 | 59 | 62 |