Boilers floor flue gas ATON Atmo – devices designed for heating and DHW with the use of automatic protection and control and provision of economic use of gaseous fuels.
The range of floor flue boiler ATON Atmo Represented by single-circuit and bypass boilers with capacity from 8 to 30 kW with an open combustion chamber.
The devices are installed in uninhabited premises (kitchen, hallway, etc.) of private houses, buildings and other public purposes, equipped with a water heating with natural (due to the difference in the density of hot and cold water) circulation and hot water system, operate on the low-pressure natural gas.
Nonvolatile boilers have low hydraulic resistance and circulate the water without a pump.
Title | units | 8ЕМ | 10ЕМ | 12ЕМ | 12ЕВМ | |
The material of boiler heat exchanger | Steel | Steel | Steel | Steel | ||
Material of heat exchanger DHW | - | - | - | Copper | ||
Efficiency (the lower heat of combustion) | % | 90 | 90 | 90 | 90 | |
The combustion gases | Natural | |||||
Топливо | Natural gas in accordance with GOST 5542 | |||||
Nominal gas pressure | mbar | 13 | 13 | 13 | 13 | |
Nominal capacity | kW | 8 | 10 | 12,5 | 12,5 | |
Maximal fuel consumption | m³/h | 0,94 | 1,2 | 1,45 | 1,45 | |
Flue diameter (internal) | mm | 110 | 110 | 110 | 110 | |
The temperature of the combustion products | ºС | 110 | 110 | 110 | 110 | |
Regulation range of heating | ºС | 50-90 | 50-90 | 50-90 | 50-90 | |
Productivity due to DHW, Δ 35ºС | l/min | - | - | - | 5 | |
Maximum operating pressure of the heating circuit | bar | 1 | 1 | 1 | 1 | |
Maximum operating pressure of the DHW circuit | bar | - | - | - | 6 | |
Connecting the heating circuit | inch | 1½ | 1½ | 1½ | 1½ | |
Connecting the DHW circuit | inch | - | - | - | 1/2 | |
Gas connection | inch | 1/2 | 1/2 | 1/2 | 1/2 | |
Overall dimensions: | ||||||
Height | mm | 760 | 760 | 760 | 760 | |
Width | mm | 320 | 380 | 380 | 380 | |
Length | mm | 385 | 385 | 385 | 385 | |
Weight | kg | 36 | 44 | 47 | 49 |
Title | units | 16ЕМ | 16ЕВМ | 20ЕМ | 25ЕМ | 30ЕМ | |||
The material of boiler heat exchanger | Steel | Steel | Steel | Steel | Steel | ||||
Material of heat exchanger DHW | - | Copper | - | - | - | ||||
Efficiency (the lower heat of combustion) | % | 90 | 90 | 90 | 90 | 90 | |||
The combustion gases | Natural | ||||||||
Топливо | Natural gas in accordance with GOST 5542 | ||||||||
Nominal gas pressure | mbar | 13 | 13 | 13 | 13 | 13 | |||
Nominal capacity | kW | 16 | 16 | 20 | 25 | 30 | |||
Maximal fuel consumption | m³/h | 1,8 | 1,8 | 2,4 | 2,8 | 3,3 | |||
Flue diameter (internal) | mm | 125 | 125 | 125 | 135 | 145 | |||
The temperature of the combustion products | °С | 110 | 110 | 110 | 110 | 110 | |||
Regulation range of heating | °С | 50-90 | 50-90 | 50-90 | 50-90 | 50-90 | |||
Производительность по ГВС, Δ35°С | l/min | - | 4 | - | - | - | |||
Maximum operating pressure of the heating circuit | bar | 1 | 1 | 1 | 1 | 2 | |||
Maximum operating pressure of the DHW circuit | bar | - | 6 | - | - | - | |||
Connecting the heating circuit | inch | 1½ | 1½ | 2 | 2 | 2 | |||
Connecting the DHW circuit | inch | - | 1/2 | - | - | - | |||
Gas connection | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | |||
Overall dimensions: | |||||||||
Height | mm | 898 | 898 | 898 | 898 | 898 | |||
Width | mm | 385 | 385 | 455 | 455 | 455 | |||
Length | mm | 477 | 488 | 477 | 477 | 477 | |||
Weight | kg | 61,4 | 65,6 | 73,5 | 78 | 83 |