Floor flue gas boilers ATON Atmo - are devices for heating and hot water with the use of automatic protection and control and provision of economic use of gaseous fuels.
The range of floor flue boiler ATON Atmo represented single-circuit and bypass boilers ranging from 8 to 50 kW with an open combustion chamber.
The devices are installed in uninhabited rooms (kitchen, hallway, etc.) of private houses, buildings and other public purposes, equipped with a water heating with natural (due to the difference in the density of hot and cold water) circulation and system of hot water, operate on natural low-pressure gas.
Nonvolatile boilers have low hydraulic resistance and circulate the water without a pump.
Title | units | 8Е | 8ЕВ | 10Е | 12Е | 12ЕВ | |
Тhe material of the boiler heat exchanger | Steel | Steel | Steel | Steel | Steel | ||
Material of heat exchanger DHW | - | Copper | - | - | Copper | ||
Efficiency (the lower heat of combustion) | % | 90 | 90 | 90 | 90 | 90 | |
The combustion gases | Natural | ||||||
Fuel | Natural gas in accordance with GOST 5542 | ||||||
Nominal gas pressure | mbar | 13 | 13 | 13 | 13 | 13 | |
Nominal capacity | kW | 8 | 8 | 10 | 12,5 | 12,5 | |
The maximum fuel consumption | m³/h | 0,89 | 0,89 | 1,11 | 1,39 | 1,39 | |
Flue diameter (internal) | mm | 110 | 110 | 110 | 110 | 110 | |
The temperature of the combustion products | ºС | 110 | 100 | 110 | 110 | 110 | |
Regulation range of heating | ºС | 50-90 | 50-90 | 50-90 | 50-90 | 50-90 | |
Productivity over the DHW, Δ 35ºС | l/min | - | 3,25 | - | - | 5 | |
Maximum operating pressure of the heating circuit | bar | 1 | 1 | 1 | 1 | 1 | |
Maximum operating pressure of the DHW circuit | bar | - | 6 | - | - | 6 | |
Connection the heating circuit | inch | 1½ | 1½ | 1½ | 1½ | 1½ | |
Connection the DHW circuit | inch | - | 1/2 | - | - | 1/2 | |
Gas connection | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | |
Overall dimensions: | |||||||
Height | mm | 754 | 754 | 754 | 754 | 754 | |
Width | mm | 264 | 264 | 324 | 384 | 384 | |
Length | mm | 565 | 565 | 565 | 565 | 565 | |
Weight | kg | 39 | 40,7 | 45 | 50 | 52,2 |
Title | units | 16E | 16EB | 20E | 25E | 30Е | 50E | ||||
Тhe material of the boiler heat exchanger | Steel | Steel | Steel | Steel | Steel | Steel | |||||
Material of heat exchanger DHW | - | Copper | - | - | - | - | |||||
Efficiency (the lower heat of combustion) | % | 90 | 90 | 90 | 90 | 90 | 90 | ||||
The combustion gases | Natural | ||||||||||
Fuel | Natural gas in accordance with GOST 5542 | ||||||||||
Nominal gas pressure | mbar | 13 | 13 | 13 | 13 | 13 | 13 | ||||
Nominal capacity | kW | 16 | 16 | 20 | 25 | 30 | 50 | ||||
The maximum fuel consumption | m³/h | 1,8 | 1,8 | 2,4 | 2,8 | 3,3 | 5,6 | ||||
Flue diameter (internal) | mm | 125 | 125 | 125 | 125 | 70х200 | 110х240 | ||||
The temperature of the combustion products | ºС | 110 | 110 | 110 | 110 | 110 | 110 | ||||
Regulation range of heating | ºС | 50-90 | 50-90 | 50-90 | 50-90 | 50-90 | 50-90 | ||||
Productivity over the DHW, Δ 35ºС | l/min | - | 4 | - | - | - | - | ||||
Maximum operating pressure of the heating circuit | bar | 1 | 1 | 1 | 1 | 2 | 2 | ||||
Maximum operating pressure of the DHW circuit | bar | - | 6 | - | - | - | - | ||||
Connection the heating circuit | inch | 1½ | 1½ | 2 | 2 | 2 | 2½ | ||||
Connection the DHW circuit | inch | - | 1/2 | - | - | - | - | ||||
Gas connection | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 3/4 | ||||
Overall dimensions: | |||||||||||
Height | mm | 960 | 960 | 960 | 960 | 1020 | 1020 | ||||
Width | mm | 324 | 324 | 384 | 384 | 435 | 580 | ||||
Length | mm | 695 | 695 | 695 | 695 | 600 | 600 | ||||
Weight | kg | 74 | 79 | 89 | 94 | 125 | 165 |